Static Equipment: Steam Generation Train, Train Salt Exchangers, Salt Storage Tanks

  • Evaluation of partial nominal and actual loads vs. project
  • Thermal shock analysis
  • Fatigue Assessment
  • Vibration analysis

Dynamic Equipment: Main Pumps, Feed Water Pumps, Molten Salt Pumps

  • Analysis of operation points vs design curves(Q min, Q max, BEP)
  • Vibration analysis
  • Analysis O&M vs operation

Main Results:

-Assessment of accumulated damage and determination of remaining life
Identification of operating limits (thermal shocks, heating ramps, flow rates)
Identification of operational improvements, maintenance improvements and mechanical improvements
Optimizing pump consumption
Identification of thermal losses
Status of general plant maintenance or plant systems