Thermal and Hydraulic Simulation of HTF/Salt Heat Exchangers
Simulation of heat exchangers according to manufacturer documentation
Analysis of operational data based on DCS
Main Results:
Optimization of energy supply and charge/discharge curve: Energy exchanged curves as a function of operating flow rates
Influence and identification of the Q HTF / Q SALTS ratio vs. tube temperature: Integration of DCS safety measures to prevent exceeding manufacturer limits
Operational limits due to vibrations
Simulation of failure events: System operation with the remaining exchangers
Key Outcomes:
Power curve as a function of the number of available exchangers
Design of a bypass system for operation in case of failure. Basic and detailed engineering