At the forefront of the Solar Thermal sector since 2006
Engineering & Consultancy in CSP Plants
Thermosolar and renewables
Activities and Capacities
Solar thermal generation technology (Concentrated Solar Power – CSP) is where all of CADE’s capabilities clearly materialize from the beginning of the sector, as a strong and reliable partner throughout the entire project life cycle, ranging from I + D to operating plants.
CADE develops new technology and engineering concepts around improving the efficiency and availability of existing CSP plants, as well as new concepts of solar thermal technology applied to the heat consuming industry.
CSP Projects
Property Engineering
Permitting. Ready-to-Build
Basic and Detail Engineering
Procurement
Construction Supervision
Commissioning
Plants in Operation
Process Solutions
Integrity and Performance Consulting
Comprehensive Modification and Improvement
Engineering
Adequacy to Level C Inspections
Technology
solidTES – Thermal Storage
processCSP – Industrial Heat
ZeroLD – Water Recovery
MSLoop – Salts CSP Plants like HTF
Digitalization
Digital Twin
InCycle
Owner’s Engineering
FEED Engineering (Front-and-End-Engineering Design)
Selection and evaluation of main equipment and systems
Technical-Economic Feasibility Studies (CAPEX-OPEX)
Generation EPC Sheets and Specifications
EPC project execution control
Permitting / Ready-to-Build
Basic Project
Project Applications and Authorizations
Processing with the Administration
(Municipal/Regional/National)
Basic and detail Engineering
Multidisciplinary engineering for conceptual and detailed development of CSP >50MW plants:
- Solar Field- HTF
- Steam Generation
- TES – Thermal storage system in molten salts
- Power Block
Procurement
Equipment, Package Units, Contractors
Specifications of purchase and technical tabulation of offers
Manufacturing and supply monitoring and monitoring
Workshop inspection and equipment reception
Construction Supervision
Civil, Mechanical Systems, I&C, Electricity
Commissioning
Definition of protocols, manuals and PEM tests
Process Solutions
Solar Field:- Hydraulic Balancing
- Performance analysis
- Tube status analysis: replacement strategies.
- HTF thermal degradation risk analysiss.
TES: Improved storage system
- Loading/unloading strategies
- Hot drainage systems
- Leak Management
- Systems (HTF / Salts)
- Simulation of salt tanks.
- HTF / Salts Exchanger Train Analysis
TGV: Exchanger Train Analysis
Feeding water system / Steam
- Desgasificator
- Power pumps
- PSV networks
- Improvements in dosing and sampling system.
- Steam turbine performance analysis
- Operating strategies to avoid operational problems (steaming, corrosion, fouling, thermal shocks)
Integrity and Performance Consulting
Condition assessment of main systems and equipment. Determination of accumulated damage, remaining life and probability of failure.
Definition and implementation of Improvement Strategies for the operation, availability and reliability of equipment and main systems (CS / HTF / TES / GV).
Integrity consulting and root cause analysis of failure in service of equipment and main systems.
Technical Consulting (owner’s advisor) for the evaluation and resolution of disputes with suppliers in relation to guarantees, performance and / or reliability of equipment and systems.
solidTES – Thermal Storage
Concrete and aggregate-based thermal storage technology
R&D
Evaluation of the Dispatchability of a Parabolic Trough Collector System with Concrete Storage – EDITOR
Feed and conceptual engineering
Integration with:
- existing processes (steam, hot water, thermal oil, air, electricity)
existing energy sources (residual heat, PV, thermal or electrical discharges) - Basic and detail engineering
- Turnkey Projects
processCSP – Industrial Heat
Solution for thermal contribution to the industry based on concentration plot with parabolic cylinder or Fresnel technology and with thermal storage.
Feed Engineering, Conceptual and Technology Assessment
Integration with existing processes (steam, hot water, thermal oil, air, cold systems)
Basic and Detail Engineering
Turnkey Projects
Digital CSP plant
Digitalization portfolio and industry 4.0 focused on solar thermal plants
Improved asset management and O&M under paradigm 4.0, from specific equipment or asset, units or systems, to complete plants
Intelligent 3D plant model:
- LASER 3D SCAN: Point clouds generation and photorealistic plant models for improved management
SMART 3D mockups: 3d model generation including asset data and information and operation and maintenance
Digital twin: real-time critical asset monitoring and analysis for decision-making and prediction:
- Condition-based and predictive maintenance
ANALYSIS-MONITORING of status, integrity, life and failure prevention of critical equipment
Complete DIGITAL TWIN of equipment or systems with sensorization, monitoring, intelligent analysis, simulation and experimentation capability, to improve the performance and efficiency of the equipment or system.
InCycle
Methodology for the analysis and optimization of renewable steam cycles.
Water Quality Analysis vs Industry Standards and Regulations
- Review of the sampling system
Review of the dosing system
Analysis of the current status of computers:- Corrosion (pitting, FAC, low tank, …)
Fouling, performance, by-passes, etc).
Accumulated damage from current operation (fatigue, thermal shocks)
- Corrosion (pitting, FAC, low tank, …)
- Identification of operational improvements to avoid detected deviations (increased service life, improved performance)
Cycle performance analysis
Reduction of leaks (PSVs, drains, purgers)
Plants we serve
Currently, 25 CSP plants operating around the world count on CADE to evaluate, optimize and improve the main systems and critical equipment of the plant
Executed Type Projects
Static Equipment: Steam Generation Train, Train Salt Exchangers, Salt Storage Tanks
- Evaluation of partial nominal and actual loads vs. project
- Thermal shock analysis
- Fatigue Assessment
- Vibration analysis
Dynamic Equipment: Main Pumps, Feed Water Pumps, Molten Salt Pumps
- Analysis of operation points vs design curves(Q min, Q max, BEP)
- Vibration analysis
- Analysis O&M vs operation
Main Results:
-Assessment of accumulated damage and determination of remaining life
Identification of operating limits (thermal shocks, heating ramps, flow rates)
Identification of operational improvements, maintenance improvements and mechanical improvements
Optimizing pump consumption
Identification of thermal losses
Status of general plant maintenance or plant systems
Thermal and hydraulic simulation of HTF/ Salts exchangers
- Simulation of heat exchangers according to manufacturer’s documentation
- Operating data analysis according to DCS
Main Results:
- Energy delivery optimization and load/discharge curve: Exchanged energy curves based on operating flow rates
- Influence and identification of ratio Q HTF / Q SALTS Vs. Tube temperature: Integration of safeties in DCS to avoid reaching the limits set by the manufacturer
- Operational limits due to vibrations
Simulation of failure events: Operation of the system with the rest of the exchangers
Main results
- Power curve depending on the number of exchangers available
- By-pass system design to operate in case of failure. Basic engineering and detail
Thermal and hydraulic simulation of the Steam Generation train
- Simulation of heat exchangers according to manufacturer’s documentation
- Operating data analysis according to DCS
Main results:
- Equipment actual response Vs. Project
- Performance analysis and power loss (heat)
- Accelerated fouling identification: low performance, DeltaP increase
- Identification of steaming and vaporization phenomena in
- Preheater: fouling, erosion.
- Identification of mechanical risks due to vibrations
- Proposed operational improvements
- Proposal and definition of DDs if required: boronscopy, thickness measurement, analysis of samples and residues (during operation, during stoppage)
- Analysis of the performance of the other equipment available under the hypothesis of failure of one of the train equipment
- Analysis of the potential flow increase in all other available equipment for production reduction compensation for equipment that fails
- By-pass system design (basic and detail engineering)
Root cause analysis to determine the origin of cracks in the roofs of salt tanks and definition of proposals for improvement and solution of the problem.
- Tank inspection (visual inspection, thickness measurement, identification of areas with internal corrosion using MRUT methodology, temperature control and measurement in hot areas of the tank)
- Operating data analysis according to DCS
- Thermal-structural simulation under standard operating conditions
- Assessment against fatigue and thermal shocks
- Tank simulation during the warm-up process
- Assessment of foundation settlements in tank structural behavior
- Vibration assessment in piping systems
- Corrosion assessment due to air tank contamination.
Stress Corrosion - Cracking Assessment (SCC).
- Chemical analysis of salts
Main results:
- Identification of mechanical risk associated with vibrations in connections
- Identification of mechanical risk in piping due to the effect of settlements
- Identification of mechanical risk due to the preheating process
- Identification of mechanical hazard due to vibrations
- Water Quality: Operating Condition Review (DCS and Plant Analytics) Vs. Recommended Values
- Effect/Impact of water quality on core equipment
- Exchangers: corrosion, depositions, loss of performance
- Steam turbine: Fouling (Na, Si, Metal oxides) and loss of performance
- Mechanical carryover analysis in Steam Generator (SuperHeater fouling and Steam Turbine)
- Review of the dosing system.
- System review and sampling procedures.
- Thermal analysis of exchangers: by-pass identification, fouling, steaming.
- Mechanical analysis of TGV exchangers (accumulated damage per operation, operational limits)
- Definition of commissioning and stop procedures for the reduction of steaming, corrosion and soiling in equipment.
- Definition of operating strategies to increase the TGV’s lifespan.
Engineering tool for steam turbine fouling monitoring
- Fouling rate calculation
- Determining times until next stop for maintenance and cleaning
- Identification of points likely to present accumulation of N2 and cumulative N2 calculation
- Evaluation of venting requirements based on their influence on downstream equipment
- Design and engineering of venting system
Thermal/hydraulic/mechanical design
Supplier selection
Supervision of manufacturer’s engineering documents
Manufacturer design review and recommendations
Workshop inspections
- Steam Generator (Kettle Type) (HTF/Steam)(SalTs/Steam)
- Steam Generator (Forced Circulation Type) (HTF/Steam)(Salts/Steam)
- Economizer (HTF/Vapor)(Salts/Vapor)
- Boronscope analysis
- Analysis of thickness measurements
- Sample analysis (analysis of elements and compounds)
Main results:
- Failure mechanism analysis: steaming, vaporization, corrosion, thermal shock, freezing, buckling, SCC, etc.
- Influence on thermal performance
- Influence on remaining life
- Proposal for monitoring and improvement measures
- Visual inspection
- Measuring thicknesses
- Identification of areas with widespread corrosion and local corrosion using MRUT methodology
- Study DCS signals
- Thermal-structural analysis against normal operating conditions and thermal shocks
- Fatigue analysis
- Performing metallography and metallographic replicas
- Study of the operating logic of the tracing system.
- Chemical analysis of salts
- Corrosion analysis. Sample analysis (analysis of elements and compounds)
Main projects:
- Analysis of mechanisms and causes of failure: overheating associated with tracing, corrosion due to salt degradation effect.
- Proposal for monitoring and improvement measures
- Defining optimal control logic
- Definition of a predictive maintenance plan.
Root cause analysis to determine the breakage origin of ball joints. Definition of corrective measures and improvement proposals. Definition of predictive maintenance plan
- Plant inspection
- Assessment of fault record
- Standard definition of failure
- Operating data analysis according to DCS
- Thermal-structural simulation of the solar collector, ball joint system and receptor tubes
- Assessment against fatigue and thermal shocks
- Analysis of the detail of the kneecaps and simulation process of blocking them
Root cause analysis to determine the breaking origin of the receptor tubes
- Plant inspection
- Assessment of fault record
- Standard definition of failure
- Operating data analysis according to DCS
- Thermal-structural simulation of the solar collector, receiver tubes and ball joints system
- Assessment against fatigue and thermal shocks
- Vacuum loss assessment in tubes
- Radiation effect assessment
Root cause analysis to determine the origin of shoes breakage and cross over deformations
- Plant inspection
- Thermal-structural analysis of the solar collector and cross over system
- Evaluation of the malfunction of the shoes and ball joint system
- Thermal shock effect assessment and fatigue analysis
- Evaluation of large cross over system deformations
Related articles